tenths AI agentsAbout7-day free trial, then $9 a month

Answers

What does an A1c of 5.7 mean? Range, labs and trends

What does an A1c of 5.7 mean?

On the ADA and CDC charts, 5.7 is the first value in the prediabetes range, which runs from 5.7% to 6.4% (39 to 47 mmol/mol). CDC puts normal below 5.7% and diabetes at 6.5% or above. The edges are not cliffs. ADA's table note says risk is continuous, extending below the lower limit of the range and becoming disproportionately greater at the higher end. Within the range, a higher A1c means a greater risk of diabetes. MedlinePlus calls the ranges "just a guide" to what is normal.

This is not clinical evidence and not medical advice. It does not replace your care team. Discuss anything here with your clinician before you act on it.

Arun Verma, co-founder of Triangle · Published

A 5.7 can show up as one line in a portal notification, ahead of any call. One result is easy to over-read, and it reads differently when two clinics or labs have measured it.

How is A1c measured?

It is a blood test that measures what share of your hemoglobin has glucose attached. Hemoglobin is the part of a red blood cell that carries oxygen, and the result is reported as a percentage. The blood can be drawn from a finger or an arm, and you don't need to fast. Because red blood cells last about 120 days, A1c works as a "weighted" average: glucose in the preceding 30 days contributes substantially more than glucose 90 to 120 days earlier, NGSP says. ADA puts the window at about 2 to 3 months. The test doesn't show sudden, temporary rises or drops.

Is one 5.7 enough, or does it get repeated?

A repeat is part of confirming a result. NIDDK's page describes a repeat test on a different day, using A1c or another test, to confirm an A1c that shows prediabetes or diabetes in someone without symptoms. Tests can also disagree: a glucose test may show diabetes when an A1c does not, which is why health care professionals repeat tests before making a diagnosis. For diabetes, ADA's Standards of Care call for two abnormal results, from different tests at the same time or from the same test at two times, unless there is unequivocal hyperglycemia. The Standards also say results close to the diagnostic threshold should prompt a repeat in 3 to 6 months.

Why can A1c results differ between labs?

Labs can use different methods, which is why a standardization program exists. NGSP says its purpose is to standardize A1c results to those of the Diabetes Control and Complications Trial (DCCT) and the UK Prospective Diabetes Study. Under ADA's Standards of Care, the test should use a method NGSP certifies as traceable to the DCCT reference assay, and outside the U.S. some assays are NGSP certified but many more are certified by IFCC (International Federation of Clinical Chemistry), "a similarly stringent process." Results can also vary within a single lab. NIDDK's example: a 6.8 percent result could come back anywhere from 6.4 to 7.2 percent on a repeat of the same sample, though stricter quality-control standards mean more precise results than in the past. That example sits at 6.8, not 5.7. Small changes in temperature, equipment or sample handling can cause this kind of variation, though they tend to affect glucose tests more than A1c.

What can push an A1c higher or lower than your average glucose?

Conditions that change how long red blood cells last, and some hemoglobin variants, can pull an A1c away from your average glucose. ADA says factors that affect hemoglobin or red blood cell turnover can affect A1c, and that where the relationship between A1c and glucose is altered, such as with some hemoglobin variants and conditions that may alter red blood cell turnover, plasma glucose criteria should be used to diagnose diabetes. Recent blood loss and transfusion can also change A1c, NIDDK says. Methods matter too. Some A1c methods can give inaccurate results when a hemoglobin variant is present, and NGSP's page lists which common methods are affected. If glucose readings and A1c are consistently far apart, ADA says that discordance should prompt evaluation for a problem or interference with either test.

Does an A1c done in the clinic match one from a lab?

They may not match. Point-of-care tests, the kind run in a clinic, may be less accurate than laboratory A1c assays, ADA says. Some point-of-care assays are NGSP certified and FDA cleared for monitoring. Sources differ on diagnosis. NIDDK's page (reviewed April 2018) says samples analyzed in a doctor's office or clinic, known as point-of-care tests, should not be used for diagnosis. ADA's 2026 Standards say that for screening and diagnosis, point-of-care testing should be limited to FDA-approved devices at CLIA-certified laboratories doing testing of moderate complexity or higher, by trained personnel. The A1c test is done in a doctor's office or at a lab, per CDC, so for two results from two places, a fair question is where each one was run.

Why do some A1c reports show mmol/mol or eAG?

A1c is reported as a percentage, and some reports add other numbers for the same result. Some laboratories report estimated average glucose (eAG), which converts the percentage to mg/dL, the unit on home glucose meters, NIDDK says. ADA's tables also give A1c in mmol/mol: 5.7% to 6.4% is 39 to 47 mmol/mol. eAG is a rough equivalent, not a match. ADA's table has no row for 5.7. Its row for 6% pairs 42 mmol/mol with an eAG of 126 mg/dL (7.0 mmol/L), with a 95% CI of 100 to 152 mg/dL. eAG also won't match daily glucose readings, because it is a long-term average.

How often is A1c rechecked, and how do you read a trend?

The sources give different intervals, so the schedule is a question for your team. For prediabetes, ADA's screening criteria say testing yearly, while CDC says a doctor will likely recommend repeating the A1c every 1 to 2 years. For diabetes, the same Standards say to assess glycemic status at least twice a year, and more often (for example every 3 months) for people not meeting glycemic goals or with recent treatment changes, among others. Comparing two results takes care. Because recent glucose counts more, A1c can rise or fall relatively quickly after large changes in glucose, NGSP says. For someone at 5.7, none of the pages cited here gives a size of change that counts as real.

What could you ask about your A1c trend, or about results from more than one clinic or lab?

A fair question for your team is how often your A1c will be rechecked and what interval fits your situation. CDC's page tells people with diabetes to ask their doctor how often is right for them. You could also ask whether a result was confirmed with a repeat or another test. With results from two practices, consider asking each one which lab ran the test and whether the method is NGSP certified, whether it was done in the clinic or sent to a lab, and which units the report uses: percent, mmol/mol or eAG. If you have had recent blood loss or a transfusion, it can help to ask whether that could affect the result. MedlinePlus suggests asking your provider what A1c percentage is healthy for you.

Sources

Start your 7-day free trialtenths is made by Triangle. 7-day free trial, then $9 a month. Cancel anytime.