Can a continuous glucose monitor help with prediabetes?
Can a continuous glucose monitor help with prediabetes?
It might, but the evidence in prediabetes is limited, and the large CGM trials have been in people with diabetes. The American Diabetes Association's main CGM recommendation in its 2026 Standards of Care, 7.15, is written for children, adolescents and adults with diabetes, not for prediabetes. The one recommendation in that section that names prediabetes is narrower than a yes. Recommendation 7.28 suggests considering technology, such as a CGM or diabetes apps, combined with online or virtual licensed coaching, to improve glycemic outcomes in people with diabetes or prediabetes. The CONNECT trial, covered below, enrolled adults with type 2 diabetes, not people with prediabetes.
This is not clinical evidence and not medical advice. It does not replace your care team. Discuss anything here with your clinician before you act on it.
Arun Verma, co-founder of Triangle · Published
Glucose sensors can now be bought without a prescription, and a prediabetes result can make one look like the next step. Most of the research behind them comes from people with diabetes, which limits how far it carries.
What did the CONNECT trial study, and does it cover prediabetes?
It studied adults with type 2 diabetes who were not using insulin, not people with prediabetes. In the 26-week trial, published in the New England Journal of Medicine on October 14, 2026, 283 adults at 22 US primary care practices were randomly assigned to a CGM (145 people) or to routine care (138). Average A1c fell from 8.8% to 7.2% with a CGM and from 8.7% to 8.0% with routine care, an adjusted difference of -0.9 percentage points (95% CI -1.1 to -0.6). The trial was industry-funded. Its abstract says it was funded by Dexcom. Its ClinicalTrials.gov record lists DexCom, Inc. as an industry lead sponsor. To enroll, people needed a screening A1c of 7.5% or higher, per that record, well above the 5.7% to 6.4% range that defines prediabetes. The authors' conclusion is limited to adults with type 2 diabetes not treated with insulin and managed in primary care, so it does not answer whether a CGM helps with prediabetes.
What does FDA's over-the-counter CGM clearance mean?
It means a CGM can be bought without a prescription. It is not a finding that one helps with prediabetes. On March 5, 2024, FDA cleared the first over-the-counter CGM, for anyone 18 or older who does not use insulin, including people without diabetes who want to better understand how diet and exercise may affect their blood sugar. In the announcement, the director of the agency's device center said the clearance lets people buy a CGM without the involvement of a health care provider. The same announcement says the device is not for people with problematic hypoglycemia (low blood sugar), because it is not designed to alert the user. It says a clinical study showed the device performed similarly to other integrated CGMs, with local infection, skin irritation and pain or discomfort among the reported adverse events. It also says users should not make medical decisions based on the device's output without talking to their health care provider. It presents no results for people with prediabetes.
How is prediabetes diagnosed, and is a CGM one of the tests?
Prediabetes is diagnosed with blood tests, and a CGM is not one of them. With prediabetes, blood sugar is higher than normal but not high enough for a type 2 diabetes diagnosis, CDC says, and you can have it for years without clear symptoms. NIDDK lists the A1C and the fasting plasma glucose test, and sometimes an oral glucose tolerance test. ADA's 2026 criteria put prediabetes at an A1C of 5.7% to 6.4%, a fasting plasma glucose of 100 to 125 mg/dL, or a 2-hour glucose of 140 to 199 mg/dL during a 75-g oral glucose tolerance test. Its diagnosis section adds that there is presently insufficient evidence to support CGM for screening or diagnosis of prediabetes or diabetes.
How do CGM readings differ from an A1c?
A CGM estimates your glucose every few minutes and keeps a running record, while an A1c is one lab result that reflects your average over about the past 3 months. NIDDK says CGM sensors estimate the glucose level in the fluid between your cells, which is very similar to the glucose level in your blood. That fluid reading correlates well with blood glucose but can lag when glucose is rising or falling rapidly, according to ADA. An A1c has the opposite blind spot. It can estimate your average blood sugar, CDC notes, although it may not account for spikes or lows. A sensor still needs a blood glucose meter as a check: ADA says all CGM systems require blood glucose monitoring to confirm accuracy, especially when a reading doesn't seem to match the situation.
What kinds of CGM are there?
Three broad kinds: prescription, over-the-counter and professional. In ADA's description, prescribed real-time CGMs have adjustable alarms and alerts, while over-the-counter ones lack alarms and alerts and can be used by people not taking diabetes medicines that raise the risk of low blood sugar. Professional CGMs are owned and applied by health care professionals and collect data, blinded or not, over a short period. NIDDK describes the professional kind as one a doctor provides and you wear for a limited time, with the data downloaded and reviewed later. Anyone can buy an over-the-counter CGM, ADA says, including people with prediabetes who wish to assess their glycemic responses to their lifestyles.
What are the limits of a CGM?
Readings are estimates, and wearing a sensor has its own drawbacks. Certain medicines and other substances can push sensor readings above actual glucose, ADA's technology section says, and people who wear a CGM should be taught about them. Recommendation 7.19 covers skin reactions from irritation or allergy, which it says should be assessed and addressed. The over-the-counter kind has no alarms, so it won't flag a low reading on its own. If you take medicines or supplements, a fair question is whether any are known to affect the sensor in question.
What could I ask a clinician about whether a CGM would add anything?
You could ask what a CGM would show your team that your A1c and fasting glucose don't already, and how they would read the two side by side. ADA says regular review of CGM data is needed to inform and optimize clinical care, so another fair question is who would look at the readings with you, and when. Other questions worth raising: whether a short professional CGM would tell you more than buying one, whether a coached program of the kind described in ADA's recommendation 7.28 is available to you, and when your next A1c is due so the readings can sit next to a lab result. If you keep a parent's results in order, the same questions work on their behalf.
Sources
- American Diabetes Association Professional Practice Committee for Diabetes: 7. Diabetes Technology: Standards of Care in Diabetes—2026, Diabetes Care 2026;49(Suppl. 1):S150–S165 ('Data From Randomized Controlled Trials'): ADA's summary of randomized controlled trials of CGM ('Data From Randomized Controlled Trials', Section 7) describes trials in people with diabetes; prediabetes appears in Section 7 only in the OTC-CGM paragraph, Recommendation 7.28 and the digital-programs paragraph, not in the trial summary.
- American Diabetes Association Professional Practice Committee for Diabetes: 7. Diabetes Technology: Standards of Care in Diabetes—2026, Diabetes Care 2026;49(Suppl. 1):S150–S165 (Recommendation 7.15): ADA's Recommendation 7.15 says use of CGM is recommended at diabetes onset and anytime thereafter for children, adolescents and adults with diabetes on insulin therapy, on noninsulin therapies that can cause hypoglycemia, and on any diabetes treatment where CGM helps in management.
- American Diabetes Association Professional Practice Committee for Diabetes: 7. Diabetes Technology: Standards of Care in Diabetes—2026, Diabetes Care 2026;49(Suppl. 1):S150–S165 (Recommendation 7.28, 'Digital Health Technology'): ADA's Recommendation 7.28 says to consider combining technology (CGM, insulin pump, and/or diabetes apps) with online or virtual licensed coaching to improve glycemic outcomes in individuals with diabetes or prediabetes (grade B).
- Continuous Glucose Monitoring in Non-Insulin-Treated Type 2 Diabetes (CONNECT), N Engl J Med, published online 2026-10-14, doi 10.1056/NEJMoa2608571 (PubMed abstract, PMID 42878622) (Methods; Results): The CONNECT abstract says the 26-week trial, at 22 primary care practices in the United States, randomly assigned adults with type 2 diabetes who were not using insulin to CGM or routine care, with 145 participants in the CGM group and 138 in the routine-care group.
- Continuous Glucose Monitoring in Non-Insulin-Treated Type 2 Diabetes (CONNECT), N Engl J Med, published online 2026-10-14, doi 10.1056/NEJMoa2608571 (PubMed abstract, PMID 42878622) (Results): The CONNECT abstract says mean glycated hemoglobin decreased from 8.8% to 7.2% at 26 weeks in the CGM group and from 8.7% to 8.0% in the routine-care group, an adjusted mean difference of -0.9 percentage points (95% CI, -1.1 to -0.6).
- Continuous Glucose Monitoring in Non-Insulin-Treated Type 2 Diabetes (CONNECT), N Engl J Med, published online 2026-10-14, doi 10.1056/NEJMoa2608571 (PubMed abstract, PMID 42878622) (publication date; funding line): The CONNECT abstract was published in the New England Journal of Medicine on 2026-10-14 and states "Funded by Dexcom".
- ClinicalTrials.gov: NCT06601166, CONtiNuous glucosE Monitoring (CGM) in People wiTh Type 2 Diabetes Not on Insulin: The CONNECT Study (record last updated 2026-08-11) (Sponsor; Enrollment): The ClinicalTrials.gov record for NCT06601166 lists DexCom, Inc. as lead sponsor, class Industry, and an actual enrollment of 283.
- ClinicalTrials.gov: NCT06601166, CONtiNuous glucosE Monitoring (CGM) in People wiTh Type 2 Diabetes Not on Insulin: The CONNECT Study (record last updated 2026-08-11) (Eligibility, inclusion criteria 2 and 3): The ClinicalTrials.gov record's inclusion criteria require a clinical diagnosis of type 2 diabetes of at least 6 months managed in a primary care setting and a screening HbA1c of 7.5% or higher.
- American Diabetes Association Professional Practice Committee: 2. Diagnosis and Classification of Diabetes: Standards of Care in Diabetes—2026, Diabetes Care 2026;49(Suppl. 1):S27–S49 (PMC copy, PMC12690183) (Table 2.2): ADA's Table 2.2 (criteria defining prediabetes) gives A1C 5.7 to 6.4% (39 to 47 mmol/mol), FPG 100 to 125 mg/dL, or 2-h PG during a 75-g OGTT of 140 to 199 mg/dL.
- Continuous Glucose Monitoring in Non-Insulin-Treated Type 2 Diabetes (CONNECT), N Engl J Med, published online 2026-10-14, doi 10.1056/NEJMoa2608571 (PubMed abstract, PMID 42878622) (Conclusions): The CONNECT abstract concludes that among adults with type 2 diabetes not being treated with insulin and managed in a primary care setting, CGM led to a greater reduction in glycated hemoglobin and a lower risk of hyperglycemia than routine care.
- FDA press announcement: FDA Clears First Over-the-Counter Continuous Glucose Monitor (March 5, 2024): FDA says that on March 5, 2024 it cleared for marketing the first over-the-counter CGM, intended for anyone 18 years and older who does not use insulin, such as individuals with diabetes treating their condition with oral medications, or those without diabetes who want to better understand how diet and exercise may impact blood sugar levels.
- FDA press announcement: FDA Clears First Over-the-Counter Continuous Glucose Monitor (March 5, 2024): In FDA's announcement, Jeff Shuren, director of FDA's Center for Devices and Radiological Health, says the clearance expands access by allowing individuals to purchase a CGM without the involvement of a health care provider.
- FDA press announcement: FDA Clears First Over-the-Counter Continuous Glucose Monitor (March 5, 2024): FDA says the system is not for individuals with problematic hypoglycemia (low blood sugar), as it is not designed to alert the user to this potentially dangerous condition.
- FDA press announcement: FDA Clears First Over-the-Counter Continuous Glucose Monitor (March 5, 2024): FDA says data from a clinical study showed the device performed similarly to other iCGMs, and that adverse events reported in the study included local infection, skin irritation and pain or discomfort.
- FDA press announcement: FDA Clears First Over-the-Counter Continuous Glucose Monitor (March 5, 2024): FDA says users should not make medical decisions based on the device's output without talking to their healthcare provider.
- FDA press announcement: FDA Clears First Over-the-Counter Continuous Glucose Monitor (March 5, 2024): FDA's announcement reports device performance compared with other iCGMs and adverse events from a clinical study; it presents no results for people with prediabetes.
- CDC: Prediabetes – Your Chance to Prevent Type 2 Diabetes (Dec. 26, 2024) ('What is prediabetes?'): CDC says that with prediabetes, blood sugar levels are higher than normal but not high enough for a type 2 diabetes diagnosis.
- CDC: Prediabetes – Your Chance to Prevent Type 2 Diabetes (Dec. 26, 2024) ('Signs and symptoms'): CDC says you can have prediabetes for years but have no clear symptoms.
- NIDDK: Insulin Resistance & Prediabetes (last reviewed March 2025) ('Blood tests'): NIDDK says health care professionals can diagnose prediabetes using blood tests, may use the A1C test and the fasting plasma glucose (FPG) test, and sometimes use an oral glucose tolerance test (OGTT).
- NIDDK: Insulin Resistance & Prediabetes (last reviewed March 2025) ('Blood tests'): NIDDK says the FPG test shows your blood glucose level at the time of the test and the A1C test shows your average blood glucose level over the past 3 months.
- American Diabetes Association Professional Practice Committee: 2. Diagnosis and Classification of Diabetes: Standards of Care in Diabetes—2026, Diabetes Care 2026;49(Suppl. 1):S27–S49 (PMC copy, PMC12690183) ('Diagnostic Tests for Diabetes', text before Table 2.2): ADA's diagnosis section says there is presently insufficient evidence to support the use of continuous glucose monitoring (CGM) for screening or diagnosis of prediabetes or diabetes.
- NIDDK: Continuous Glucose Monitoring (last reviewed June 2023) ('How does a continuous glucose monitor work?'): NIDDK says a CGM estimates what your glucose level is every few minutes and keeps track of it over time.
- NIDDK: Continuous Glucose Monitoring (last reviewed June 2023) ('How does a continuous glucose monitor work?'): NIDDK says CGM sensors estimate the glucose level in the fluid between your cells, which is very similar to the glucose level in your blood.
- American Diabetes Association Professional Practice Committee for Diabetes: 7. Diabetes Technology: Standards of Care in Diabetes—2026, Diabetes Care 2026;49(Suppl. 1):S150–S165 ('Continuous Glucose Monitoring Devices', text after Recommendation 7.20): ADA says CGM measures interstitial glucose, which correlates well with plasma glucose, although at times it can lag if glucose levels are rising or falling rapidly.
- CDC: A1C Test for Diabetes and Prediabetes (May 15, 2024) ('A1C results'): CDC says your A1C can estimate your average blood sugar, although it may not account for any spikes or lows.
- American Diabetes Association Professional Practice Committee for Diabetes: 7. Diabetes Technology: Standards of Care in Diabetes—2026, Diabetes Care 2026;49(Suppl. 1):S150–S165 ('Continuous Glucose Monitoring Devices'): ADA says all CGM systems require use of blood glucose monitoring (BGM) to confirm accuracy, especially in settings where there is perceived discordance between the sensor reading and the individual's perceived sense of their clinical situation.
- American Diabetes Association Professional Practice Committee for Diabetes: 7. Diabetes Technology: Standards of Care in Diabetes—2026, Diabetes Care 2026;49(Suppl. 1):S150–S165 ('Continuous Glucose Monitoring Devices'; Table 7.3): ADA describes two categories of CGM generally available for personal use: those prescribed for diabetes management (rtCGM), which have adjustable alarms and alerts, and over-the-counter CGM (OTC-CGM), which lacks alarms and alerts and can be used by people not taking diabetes medications that increase the risk of hypoglycemia.
- American Diabetes Association Professional Practice Committee for Diabetes: 7. Diabetes Technology: Standards of Care in Diabetes—2026, Diabetes Care 2026;49(Suppl. 1):S150–S165 ('Continuous Glucose Monitoring Devices'): ADA describes professional CGM devices as devices owned and applied by health care professionals that generate glucose data (blinded or not) over a short period of time.
- NIDDK: Continuous Glucose Monitoring (last reviewed June 2023) ('What are the different types of continuous glucose monitors?'): NIDDK describes a type of CGM that collects data for your doctor to download and review later, which doctors provide to check on your diabetes care and which you wear for a limited time.
- American Diabetes Association Professional Practice Committee for Diabetes: 7. Diabetes Technology: Standards of Care in Diabetes—2026, Diabetes Care 2026;49(Suppl. 1):S150–S165 ('Continuous Glucose Monitoring Devices'): ADA says anyone can purchase the OTC-CGM devices, including those without diabetes or with prediabetes who wish to assess their glycemic responses to their lifestyles.
- American Diabetes Association Professional Practice Committee for Diabetes: 7. Diabetes Technology: Standards of Care in Diabetes—2026, Diabetes Care 2026;49(Suppl. 1):S150–S165 (Recommendation 7.20; Table 7.4): ADA's Recommendation 7.20 says people who wear CGM devices should be educated on potential interfering substances and other factors that may affect accuracy, and its Table 7.4 lists medications and substances that give higher sensor readings than actual glucose.
- American Diabetes Association Professional Practice Committee for Diabetes: 7. Diabetes Technology: Standards of Care in Diabetes—2026, Diabetes Care 2026;49(Suppl. 1):S150–S165 (Recommendation 7.19): ADA's Recommendation 7.19 says skin reactions, either due to irritation or allergy, should be assessed and addressed to aid in successful use of devices.
- American Diabetes Association Professional Practice Committee for Diabetes: 7. Diabetes Technology: Standards of Care in Diabetes—2026, Diabetes Care 2026;49(Suppl. 1):S150–S165 ('Education and Training'): ADA says regular monitoring and review of the data obtained from CGM devices is needed to inform and optimize clinical care.
Start your 7-day free trialtenths is made by Triangle. 7-day free trial, then $9 a month. Cancel anytime.